IEEE STD 242-2001 Recommended Practice for Protection and by IEEE

By IEEE

This IEEE criteria product is a part of the colour Books kinfolk.

Show description

Read Online or Download IEEE STD 242-2001 Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems PDF

Similar industrial books

Industrial Metrology: Surfaces and Roundness

The topic of this e-book is floor metrology, particularly significant elements: floor texture and roundness. It has taken many years for production engineers and architects to grasp the usefulness of those gains in caliber of conformance and caliber of layout. regrettably this expertise has come at a time whilst engineers versed within the use and specification of surfaces are at a top rate.

Advances in Solar Energy Technology: Volume 2: Industrial Applications of Solar Energy

The aim of scripting this 3 quantity 'Advances in solar power know-how' is to supply the entire suitable most recent info to be had within the box of solar power (Applied in addition to Theoretical) to function the simplest resource fabric at one position. makes an attempt are made to debate themes extensive to aid either the scholars (i.

Industrial Enzymes: Structure, Function and Applications

Man's use of enzymes dates again to the earliest instances of civilization. very important human actions resembling the creation of specific sorts of meals and drinks, and the tanning of hides and skins to supply leather-based for clothes, serendipitously took benefit of enzyme actions. very important advances in our figuring out of the character of enzymes and their motion have been made within the past due nineteenth and early twentieth centuries, seeding the explosive growth from the Nineteen Fifties and 60s onward to the current billion greenback enzyme undefined.

Additional info for IEEE STD 242-2001 Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems

Sample text

Today, most analysts choose to perform these calculations using computers, and the procedure outlined in Item a) through Item h) assumes that computers are used. However, the basic principles apply to manual calculations although the analyst in that instance should be more careful to decide up front precisely what information is needed in order to minimize the amount of tedious work to be done. a) b) c) State the problem to be solved. The nature of the problem determines the type of calculation to be done and, in turn, dictates what specific data are required.

Many ground relays are wired to receive the residual current from a set of three-phase current transformers (CTs) and, as such, measure a physical current that can be described in the language of symmetrical components as three times the zero-sequence branch current. Often, computer programs produce the zero-sequence current distribution without the three multiplier. 8 kV feeder serving the 2 Mvar power factor capacitor on Bus 4. 8 kV, 2 Mvar capacitor feeder on Bus 4. 65) is present due primarily to the close proximity of the generator, which contributes 4080 A of symmetrical current.

Positive-sequence reactance is also usually available from the generator manufacturer’s data sheet, but normally several values exist from which to choose. As noted in Table 2-1, the value to be used in a calculation of short-circuit currents depends upon the intended use of the result of that calculation. The definitions given in Equation (2-5) for positive-, negative-, and zero-sequence voltage and current phasor sets also suggest another important consideration in the representation of synchronous machines in symmetrical component terminology.

Download PDF sample

Rated 4.65 of 5 – based on 5 votes